PRODUCTS
ASAHI TECHNOLOGY

Graphite electrode


Carbon products are widely used in many fields, including metallurgy, chemical engineering, aviation, and aerospace.


Product Details

Standard dimensions and weight of graphite electrodes

Nominal diameter

Diameter range (mm)

Length range (mm)

Standard weight (kg)

inch

mm

Max.

 

Min.

Nominal

Max.

 

Min.

 

Length

3

75

78

~

73

1000

1050

~

925

7

4

100

103

~

98

1200

1250

~

1100

16

5 1/8

130

132

~

129

1500

1550

~

1400

33

6

150

154

~

149

1500

1550

~

1400

45

7

175

179

~

174

1500

1550

~

1400

59

8

200

205

~

200

1500

1550

~

1400

76

1800

1875

~

1700

100

9

225

230

~

225

1500

1550

~

1400

101

10

250

256

~

251

1500

1550

~

1400

120

1800

1875

~

1700

155

12

300

307

~

302

1500

1550

~

1400

185

1800

1875

~

1700

230

14

350

357

~

352

1500

1550

~

1400

253

1800

1875

~

1700

305

2400

2475

~

2275

406

16

400

409

~

403

1500

1550

~

1400

334

1800

1875

~

1700

395

18

450

460

~

454

1800

1875

~

1700

505

2100

2175

~

1975

585

2400

2475

~

2275

665

20

500

511

~

505

1800

1875

~

1700

617

2100

2175

~

1975

717

2400

2475

~

2275

824

22

550

562

~

556

2100

2175

~

1975

873

2400

2475

~

2275

995

24

600

613

~

607

2400

2475

~

2275

1190

2700

2850

~

2550

1350

26

650

663

~

657

2700

2850

~

2550

1580

28

700

714

~

708

2700

2850

~

2550

1840

Instructions for Use of Graphite Electrodes

1

1

Before connecting the electrode, first thoroughly clean the threads on the electrode. When carefully screwing the coupling onto one end of the electrode, simultaneously screw the lifting coupling onto the other end of the electrode—taking care not to damage the threads. It is not recommended to directly install the coupling onto an electrode that is already in use in the furnace.

2

2

Absolutely no steel wool or metal brushes, nor sandpaper, should be used to clean the electrode threads. Only compressed air free of oil and water may be used for cleaning.

3

3

To use the elastic hook with a rotatable feature, place a soft support pad beneath the electrode connector to prevent damage to the threads.

4

4

Before connecting the electrodes, the holes should be thoroughly cleaned with compressed air that is free of oil and water.

5

5

Use an elastic hook to lift and transport the electrode to the furnace, align it precisely with the center, lower it slowly, gently rotate it into place, and then tighten it securely with a hoop ring.

6

6

Tighten using a dedicated caliper at the specified torque—either mechanically, hydraulically, or with pneumatic equipment—until the designated torque is reached.

7

7

If the end faces of the two electrodes do not make contact or if the contact pressure is too high, normal operation will be affected.

8

8

The electrode holder must be positioned outside the two white warning lines. The contact surface between the holder and the electrode should be cleaned regularly to ensure good electrical contact. The cooling water jacket of the holder must be kept completely leak-free.

9

9

To prevent electrode breakage, no insulating material blocks should be loaded into the furnace. The operating current of the electrode must be compatible with the electrode’s allowable current specified in the instruction manual.

10

10

To prevent the electrode from breaking, place larger pieces at the bottom and smaller pieces at the top.

Quote inquiry

Please provide your contact information and specify your requirements, and we’ll arrange for a specialist to get in touch with you!

  • 您需要多少产品?
  • 您还需要了解什么信息?
Submit